Tel: +86-13333857585     E-mail: inquiry@otywell-detector.com

About   Contact    |   

S600Ex-IR3 Infrared Flame Detector (Triple IR, Explosion-proof) - Otywell | Gas Analyzer Manufacturer

Flame Detector/

S600Ex-IR3 Infrared Flame Detector (Triple IR, Explosion-proof)

Response spectral range:4.4μm, 5.0μm, 3.8μm

Response time:6s

Viewing angle range:≤110 °

Detection distance:Class I

Ambient temperature:-10 ~ 55 ℃

Environmental humidity:≤95% RH

Pressure range:86 ~ 106Kpa

Working voltage:DC24V

Working current:current≤25mA, alarm current≤35mA

Executive standard:GB15631-2008

Explosion-proof grade:Ex d ⅡC T6 Gb

Protection grade:IP66

Signal output:Switching relay contact output, RS-485 (built-in DIP switch, can set the address of the detector)

Installation method:wall or ceiling

Cable outlet thread:20mmX1.5mm free conversion G1 / 2 optional

Dimensions:(190X160X110) mm

Shell material:die-cast aluminum

Weight:1Kg

Advantages:dustproof, explosion-proof, corrosion-proof

  • Product Details

Description

The S600-ExIR3 three-wavelength point-type infrared flame detector contains three infrared sensors and optical filters. The main sensor has the highest sensitivity to the CO2 emission spectrum (4.4 μm) generated by the combustion of hydrocarbons, and the other two infrared sensor pairs The detection of ambient light and background light interference from thermal body radiation. The detector has multiple signal processing algorithms, combined with logical comprehensive judgment of the flame flicker frequency, to maximize the suppression of false alarms and the best fire detection performance. The special fire signal processing method and multi-sensor detection technology greatly improve the sensitivity and response time of the detector. The detector is suitable for liquid and gas fires, open flames with smoke and places where deflagration occurs.

Functions Features

Technical Parameters

Response spectral range4.4μm, 5.0μm, 3.8μm
Response time6s
Viewing angle range≤110 °
Detection distanceClass I
Ambient temperature-10 ~ 55 ℃
Environmental humidity≤95% RH
Pressure range86 ~ 106Kpa
Working voltageDC24V
Working currentcurrent≤25mA, alarm current≤35mA
Executive standardGB15631-2008
Explosion-proof gradeEx d ⅡC T6 Gb
Protection gradeIP66
Signal outputSwitching relay contact output, RS-485 (built-in DIP switch, can set the address of the detector)
Installation methodwall or ceiling
Cable outlet thread20mmX1.5mm free conversion G1 / 2 optional
Dimensions(190X160X110) mm
Shell material:die-cast aluminum
Weight1Kg
Advantagesdustproof, explosion-proof, corrosion-proof

Prev: