Descrição
Electrochemical Carbon monoxide gas sensor utilizes the electro-chemical activity of the gas under measurement to undergo elec-trochemical oxidation or reaction inside it, thereby converting the content of the gas under measurement into a current (or voltage) signal output to distinguish the composition and concentration of the gas.
Recursos de funções
- Good long-term stability
- High consistency and high precision
- Fast response speed
- Strong anti-cross interference ability,
- Good linearity
- Strong adaptability to harsh environments
High Sensitivity
Good Selectivity
Fast Response Time
High Stability
Parâmetros Técnicos
| Gás de detecção | Carbon monoxide CO |
| Sensibilidade | 70±20nA/ppm |
| Typical baseline range (pure air) | ±2ppm CO equivalent |
| T90 response time | <30 segundos |
| Faixa | 0-2000ppm |
| Maximum load | 5000ppm |
| Linear range | 0-2000ppm |
| Repeatability | +2%ppm CO equivalent |
| Recommended load resistance | 10Ω |
| Operating temperature range | -30- + 50°C |
| Faixa de pressão | 800-1 200mbar |
| Humidity range | 1 5% – 95%RH |
| Long-term output drift | < 5% per year |
| Storage temperature | 0- -20℃ |
| Expected working life | > 24 meses |
| Warranty period | 12 meses |
| 2000ppm maximum current | 0.3mA |
| Maximum 0/C voltage | 1.3V |
| Maximum S/C current | < 1A |
MARCAÇÃO: otywell gas sensor,O2 sensor ,H2S sensor,CO sensor,PID sensor,voc sensor
E-mail:inquérito@otywell-safety.com
Mobile/WhatsApp:+8616692113216
Observação: Nem todos os gases e faixas estão listados, se você precisar de mais informações, entre em contato conosco.
| Listagem de parâmetros de gás comum | ||||
| Gás detectado | Faixa de medição | Faixa opcional | Resolução Rato | Tempo de resposta |
| LEL - gás combustível | 0-100%LEL | 0-100%VOL (infravermelho ou catalítico) | 1%LIE/1% vol | ≤10s |
| monóxido de carbono | 0-1000PPm | 0-500/2000/5000PPm | 0.1/1PPm | ≤10s |
| TVOC | 0-100PPM | 0-100PPM | 0.1PPm/1PPM | ≤15s |
| hidrogênio | 0-100%LEL | 0-1000PPM | 1%LEL/1PPM | ≤15s |
| gás natural | 0-100%LEL | 0-100%LEL | 1%LEL | ≤10s |
| Oxigênio-O2 | 0-30%volume | 0-30%、0-100%volume | 0.1%volume | ≤10s |
| ozônio | 0-10PPm | 0-20、100PPm | 0.01PPm/0,1PPM | ≤15s |
| sulfeto de hidrogênio-H2S | 0-100PPm | 0-50、200、1000PPm | 1/0.1PPm | ≤10s |
| Metano-CH4 | 0-100%LEL | 0-100%volume | 1%LIE/1% vol | ≤10s |
| flúor | 0-10PM | 0-1、10PPM | 1/0.1PPm | ≤15s |
| cloreto de hidrogênio | 0-20PPm | 0-20/50PPm/100PPM | 0.01/0.1PPm | ≤15s |
| Nitrogênio-N2 | 0-30%volume | 0-30%volume、100%volume | 0.1%LEL/1PPM | ≤10s |
| hidrogênio | 0-100%LEL | 0-1000PPm | 1%LEL/0,1PPm | ≤15s |
| cloro | 0-20PPm | 0-10、100PPm | 0.1PPm | ≤15s |
| gás amônia | 0-100PPm | 0-50、500、1000PPm | 1/0.1PPm | ≤15s |
| oxinitreto | 0-20PPm | 0-50、1000PPm | 0.1/1PPm | ≤15s |
| metanal | 0-20PPm | 0-50、100PPm | 1/0.1PPm | ≤15s |
| dióxido de enxofre | 0-20PPm | 0-50、1000PPm | 0.1/1PPm | ≤15s |
| óxido nítrico | 0-250PPm | 0-500、1000PPm | 1PPm | ≤15s |
| dióxido de nitrogênio | 0-20PPm | 0-50、1000PPm | 0.1/1PPm | ≤15s |
| fosfina | 0-20PPm | 0-20、100PPm | 0.1PPm | ≤15s |
| acrilonitrila | 0-100PPM | 0-100PPm | 0.1/1PPm | ≤15s |
| dióxido de carbono | 0-5000PPm | 0-1%/5%/10%volume(Infravermelho ) | 1PPM/0,01%VOL | ≤15s |
| fluoreto de hidrogênio | 0-10PPm | 0-1、10、50、100PPM | 0.01/0.1PPm | ≤15s |
| Xileno/metilbenzeno | 0-20PPm | 0-5、10、50、100PPm | 0.01/0.1PPm | ≤15s |
| oxirano | 0-100PPm | 0-100PPm | 1/0.1PPm | ≤15s |
| Para outros gases e faixas de medição, por favor entre em contato conosco diretamente! | ||||
Observação: Nem todos os gases e faixas estão listados, se você precisar de mais informações, entre em contato conosco.
MARCAÇÃO: otywell gas sensor,O2 sensor ,H2S sensor,CO sensor,PID sensor,voc sensor
E-mail:inquérito@otywell-safety.com
Mobile/WhatsApp:+8616692113216
Otywell | Fabricante de detectores de gás










WeChat
Digitalize o código QR com WeChat