Detection principle: laser detection

Detection gas: dust

Sampling method: natural aspiration

Measurement range: 1ug/m³~1000ug/m³; 1mg/m³~1000 mg/m³; 0~10.000mg/m3 (other optional)

Resolution: 1ug/m³; 1mg/m³

Detection error: full scale ±10%FS

Status indication: LCD indication

Debugging method: remote control

Response time: <20s

Recovery time: <30s

Ambient temperature: -20℃~55℃

Relative humidity: ≤95%RH

Working voltage: DC24V±10%

Explosion-proof grade: Ex d ib IIC T6 Gb

Output signal: 4~20mA/RS485

  • Product Details

Description

TCB1000 dust and gas detector uses infrared detection principle or laser detection principle to transmit dust particles in the use environment over long distances as electrical signals, and transmit the signals to the secondary instrument. This instrument can be directly uploaded to the computer or connected to the DCS system.

The dust and gas detector has the functions of on-site buzzer indication sound, flashing indicator light, etc., and real-time display and monitoring of on-site dust concentration.

The dust and gas detector can be used in chemical plant areas, smelting, papermaking, flour mills, coal mining plants, pharmaceutical workshops, petroleum refining, mining and electricity, fire protection and municipal administration, communications and other industrial environments that need to prevent dust explosions.

product features

  • Sound and light integrated alarm
  • Accurate measurement: The sensor adopts imported gas sensitive elements, with high accuracy and small zero drift
  • Wireless remote control technology
  • Natural diffusion detection
  • Two groups of switch signals
  • Double cavity structure

Technical Parameters

Detection principle Laser detection
Detection gas Dust
Sampling method Naturally aspirated
Measurement range pm2.5/pm10, 1ug / m³ ~ 1000ug / m³; 1mg / m³ ~ 1000 mg / m³; (other optional)
Resolution 1ug / m³; 1mg / m³
Detection error: ± 10% FS of full scale
Status indication LCD indication
Debug mode Remote control
Response time <20s
Recovery time <30s
Ambient temperature -20 ℃ ~ 55 ℃
Relative humidity ≤95% RH
Working voltage: DC24V ± 10%
Explosion-proof grade Exd ib IIC T6 Gb
Output signal 4 ~ 20mA / RS485

 