Tel: +86-13333857585 E-mail: indagry@otywell-detector.com

Di Contatto |

S600EX-IR2-UV Rilevatore di fiamme a doppio spettro (Dual Ir, Singolo UV) - Otywell | Produttore di analizzatore di gas

Rilevatore di fiamma/

S600EX-IR2-UV Rilevatore di fiamme a doppio spettro (Dual Ir, Singolo UV)

Response spectral range4.4μm, 3.8μm, 185-260nm

Tempo di risposta:6S

Viewing angle range≤110 °

Detection distanceClass I

Temperatura ambiente:-10 ~ 55 ℃

Environmental humidity≤95% RH

Pressure range86 ~ 106Kpa

Tensione di lavoro:DC24V

Working currentcurrent≤25mA, alarm current≤35mA

Executive standardGB15631-2008, GB12791-2006

Explosion-proof gradeEX d ⅡC T6 Gb

Protection gradeIP66

Signal outputSwitching relay contact output, RS-485 (built-in DIP switch, can set the address of the detector)

Installation methodwall or ceiling

Cable outlet thread20mmX1.5mm free conversion G1 / 2 opzionale

Dimensioni:(190X160X110) mm

Shell materialdie-cast aluminum

Peso:1Kg

Advantagespolvere, a prova di esplosione, corrosion-proof

  • Dettagli del prodotto

Descrizione

S600-ExIR2-UV point type infrared / UV flame detector contains two infrared wavelength sensors and a highly sensitive imported UV/ultraviolet sensor and optical filter. The ultraviolet sensor can respond to ultraviolet radiation at the moment of fire and explosive ignition. The other two infrared sensors, one has the highest sensitivity to the CO2 emission spectrum (4.4μm), and the other interferes with ambient light and heat radiation For detection, the detector makes a composite judgment on the ultraviolet and infrared signals generated in the event of a fire, and performs multi-signal processing in conjunction with the logical comprehensive judgment of the flame flicker frequency to minimize false alarms and the best fire detection performance required. The flame detector has an early warning function for the fire of organic materials such as hydrocarbons and the fire of inorganic materials.

Funzioni Caratteristiche

Parametri tecnici

Response spectral range 4.4μm, 3.8μm, 185-260nm
Tempo di risposta 6S
Viewing angle range ≤110 °
Detection distance Class I
Temperatura ambiente -10 ~ 55 ℃
Environmental humidity ≤95% RH
Pressure range 86 ~ 106Kpa
Tensione di lavoro DC24V
Working current current≤25mA, alarm current≤35mA
Executive standard GB15631-2008, GB12791-2006
Explosion-proof grade EX d ⅡC T6 Gb
Protection grade IP66
Signal output Switching relay contact output, RS-485 (built-in DIP switch, can set the address of the detector)
Installation method wall or ceiling
Cable outlet thread 20mmX1.5mm free conversion G1 / 2 opzionale
Dimensioni (190X160X110) mm
Shell material die-cast aluminum
Peso 1Kg
Advantages polvere, a prova di esplosione, corrosion-proof