Sensore di ossigeno industriale R-4OX

Long Term Output Drift< 5% per annum
Recommended Storage Temp0℃to 20℃
Expected Operating Life> 24 months in air
Standard Warranty24 months from date of dispatch

 

TAG: otywell gas sensorO2 sensorH2S sensorCO sensorNH3 sensor

E-mail:inchiesta@otywell-safety.com

Mobile/whatsapp:+8616692113216

  • Dettagli del prodotto

Descrizione

The R-40X electrochemical oxygen sensor utilizes the electro-chemical activity of the gas under measurement to undergo elec-trochemical oxidation or reaction inside it, thereby converting the content of the gas under measurement into a current (or voltage) signal output to distinguish the composition and concentration of the gas.

Funzioni Caratteristiche

  • Good stability
  • High precision
  • Fast response speed
  • Anti-cross interference
  • Linear optimization
  • Strong adaptability

Parametri tecnici

Lifetime Details

Long Term Output Drift< 5% per annum
Recommended Storage Temp0℃to 20℃
Expected Operating Life> 24 months in air
Standard Warranty24 months from date of dispatch

 

Intrinsic Safety Data

Maximum current in normal operation (pure O2)0.01 A
Maximum o/c Voltage (10 A 100% O2)0.9 V
Maximum s/c Current (10 A 100% O2)0.5 A

 

Erformance Characteristics

Segnale di uscita0.10 ± 0.03 mA
Zero Current (Offset)< 0.6% vol. O2
Tempo di risposta T90< 15 secondi
Intervallo di misurazione0 – 25% Ossigeno
Maximum Overload30% Ossigeno
LinearityLinear
Recommended Load Resistor100 ohms

 

Environmental Details

Temperature Range Continuous-30℃to +50℃
Pressure Range800 A 1200 mbar
Operating Humidity Range5% A 95% RH

Toxic gases at TLV levels will have no cross-sensitivity effect on oxygen sensors. At very high levels (i.e. percent levels), highly oxidising gases (e.g. ozono, cloro) will interfere to the extent of their oxygen equivalent, but most other commonly occurring gases will have no effect.

Important Note:

Acid gases such as CO2 and SO2 will be absorbed by the electrolyte and tend to increase the flux of oxygen to the electrode. This gives an enhanced oxygen signal of approximately 0.3% of signal per 1% CO2.Oxygen sensors are not suitable for continuous operation in concentrations of CO2 above 25%.
All performance data is based on conditions at 20℃, 50%RH and 1 atm, using recommended circuitry.
Sensor performance is temperature dependent, and please Contact us for temperature performance other than 20℃.

 

TAG: otywell gas sensorO2 sensorH2S sensorCO sensor

 

E-mail:inchiesta@otywell-safety.com

Mobile/whatsapp:+8616692113216

Nota: Not all gases and range are listed, if you need more information, please contact us.

Elenco dei parametri dei gas comuni
Rilevato gasCampo di misuraGamma opzionaleRisoluzione RattoTempo di risposta
LEL -gas combustibile0-100%LEL0-100%VOL(Infrarossi o catalitici)1%LEL/1% vol≤10s
monossido di carbonio0-1000P/min0-500/2000/5000P/min0.1/1P/min≤10s
TVOC0-100PPM0-100PPM0.1ppm/1 ppm≤15 secondi
idrogeno0-100%LEL0-1000PPM1%LEL/1 PPM≤15 secondi
gas naturale0-100%LEL0-100%LEL1%LEL≤10s
Ossigeno-O20-30%VOL0-30%、0-100%VOL0.1%vol≤10s
ozono0-10P/min0-20、100P/min0.01ppm/0,1 ppm≤15 secondi
idrogeno solforato-H2S0-100P/min0-50、200、1000P/min1/0.1P/min≤10s
Metano-CH40-100%LEL0-100%VOL1%LEL/1% vol≤10s
fluoro0-10PM0-1、10PPM1/0.1P/min≤15 secondi
cloruro di idrogeno0-20P/min0-20/50ppm/100 ppm0.01/0.1P/min≤15 secondi
Azoto-N20-30%VOL0-30%VOL、100%VOL0.1%LEL/1 PPM≤10s
idrogeno0-100%LEL0-1000P/min1%LEL/0,1 PPm≤15 secondi
cloro0-20P/min0-10、100P/min0.1P/min≤15 secondi
gas di ammoniaca0-100P/min0-50、500、1000P/min1/0.1P/min≤15 secondi
ossinitruro0-20P/min0-50、1000P/min0.1/1P/min≤15 secondi
metanale0-20P/min0-50、100P/min1/0.1P/min≤15 secondi
anidride solforosa0-20P/min0-50、1000P/min0.1/1P/min≤15 secondi
ossido nitrico0-250P/min0-500、1000P/min1P/min≤15 secondi
biossido di azoto0-20P/min0-50、1000P/min0.1/1P/min≤15 secondi
fosfina0-20P/min0-20、100P/min0.1P/min≤15 secondi
acrilonitrile0-100PPM0-100P/min0.1/1P/min≤15 secondi
anidride carbonica0-5000P/min0-1%/5%/10%VOL(Infrarossi )1PPM/0,01%VOL≤15 secondi
acido fluoridrico0-10P/min0-1、10、50、100PPM0.01/0.1P/min≤15 secondi
Xilene/metilbenzene0-20P/min0-5、10、50、100P/min0.01/0.1P/min≤15 secondi
ossirano0-100P/min0-100P/min1/0.1P/min≤15 secondi
Per altri gas e campi di misura, per favore contattaci direttamente!

Nota: Not all gases and range are listed, if you need more information, please contact us.

 

TAG: otywell gas sensorO2 sensorH2S sensorCO sensor

 

E-mail:inchiesta@otywell-safety.com

Mobile/whatsapp:+8616692113216

Prec:

Prossimo:

Inchiesta

    PersonaleAttività commercialeDistributore

    Lasciate un messaggio