Tél: +86-13333857585 E-mail: enquête@otywell-tector.com

À propos Contact |

Détecteur de flammes à énergie solaire avec téléchargement de données NB-IOT - Otywell | Fabricant d'analyseurs de gaz

Détecteur de flamme/

Détecteur de flammes à énergie solaire avec téléchargement de données NB-IOT

Detection principlered/UV light

Wavelength rangeinfrared 4.4μm ultraviolet 185 ~ 260nmUV

Battery specification3.6V/10000mAh

Solar energy2X1W

Camera30W pixels

Spirit acuityLevel 1

Response time< 30s

Preheating time60s

Flame detection delay3S

Température ambiante:-10℃ ~ 55℃; The maximum surface temperature of the shell shall not exceed 80℃

Humidité relative:< 93%RH

Explosion-proof modeType de feuille de flambeau

Explosion-proof gradeEx dⅡC T6Gb

Protection gradeIP67

Indicatorgreen indicates early warning, red indicates alarm, blue data upload, yellow fault

Weight≤1200g

Dimensions235mm x170mm x125mm (without antenna)

Pressure limit86KPa ~ 106KPa

Use placeUse in dangerous places with explosive combustible gas IIA~IIC class and temperature group of T1~T6

  • Détails du produit

Description

The flame detector uses IoT infrared sensors and a smart cloud IoT management platform to address the traditional problems ofdifficult detection, late detection, and difficult networkingin fire monitoring. It enables early detection, early warning, and early response to forest fires, thereby avoiding greater losses. The detector also has an anti-tampering feature that triggers an alarm if the detector is moved abnormally.

Fonctions fonctionnalités

Paramètres techniques

Detection principle red/UV light
Wavelength range infrared 4.4μm ultraviolet 185 ~ 260nmUV
Battery specification 3.6V/10000mAh
Solar energy 2X1W
Camera 30W pixels
Spirit acuity Level 1
Response time < 30s
Preheating time 60s
Flame detection delay 3S
Température ambiante -10℃ ~ 55℃; The maximum surface temperature of the shell shall not exceed 80℃
Humidité relative < 93%RH
Explosion-proof mode Type de feuille de flambeau
Explosion-proof grade Ex dⅡC T6Gb
Protection grade IP67
Indicator green indicates early warning, red indicates alarm, blue data upload, yellow fault
Weight ≤1200g
Dimensions 235mm x170mm x125mm (without antenna)
Pressure limit 86KPa ~ 106KPa
Use place Use in dangerous places with explosive combustible gas IIA~IIC class and temperature group of T1~T6

Crévuré: