Tel: +86-13333857585 Correo electrónico: consulty@otywell-detector.com

Acerca de Contacto |

Detector de llama infrarroja de tipo S600-EXIR3-UV (tres IRS único UV, tipo flameproof) - Otywell | Fabricante de analizador de gas

Detector de llamas/

Detector de llama infrarroja de tipo S600-EXIR3-UV (tres IRS único UV, tipo flameproof)

Response spectral range4.4μm, 5.0μm, 3.8μm, 185-260Nuevo Méjico

Tiempo de respuesta:6s

Viewing angle range≤110 °

Detection distanceClase I

Temperatura ambiente:-10 ~ 55 ℃

Environmental humidity≤95% RH

Pressure range86 ~ 106Kpa

Working voltageDc24v

Working currentcurrent≤25mA, alarm current≤35mA

Executive standardGB15631-2008, GB12791-2006

Explosion-proof gradeEXdⅡCT6

Protection gradeIP66

Signal outputSwitching relay contact output, RS-485 (built-in DIP switch, can set the address of the detector)

Installation methodwall or ceiling

Cable outlet thread20mmX1.5mm free conversion G1 / 2 opcional

Dimensiones:(190X160X110) mm

Shell materialdie-cast aluminum

Peso:1Kg

Advantagesa prueba de polvo, explosión, corrosion-proof

  • Detalles del producto

Descripción

S600-ExIR3-UV point-type infrared flame detector contains three infrared sensors and optical filters. The main sensor has the highest sensitivity to the CO2 emission spectrum (4.4μm) produced by the combustion of hydrocarbons, and the other three infrared sensor pairs The detection of ambient light and background light interference from thermal body radiation. El detector tiene múltiples algoritmos de procesamiento de señales, combined with the logical comprehensive judgment of the flame flicker frequency, to maximize the suppression of false alarms and the best fire detection performance. The special fire signal processing method and multi-sensor detection technology greatly improve the sensitivity and response time of the detector. The sensitivity of the detector can be adjusted automatically according to changes in the use environment. El detector es adecuado para incendios líquidos y de gas, llamas abiertas acompañadas de humo, and places where deflagration occurs.

Funciones de funciones

Parámetros técnicos

Response spectral range 4.4μm, 5.0μm, 3.8μm, 185-260Nuevo Méjico
Tiempo de respuesta 6s
Viewing angle range ≤110 °
Detection distance Clase I
Temperatura ambiente -10 ~ 55 ℃
Environmental humidity ≤95% RH
Pressure range 86 ~ 106Kpa
Working voltage Dc24v
Working current current≤25mA, alarm current≤35mA
Executive standard GB15631-2008, GB12791-2006
Explosion-proof grade EXdⅡCT6
Protection grade IP66
Signal output Switching relay contact output, RS-485 (built-in DIP switch, can set the address of the detector)
Installation method wall or ceiling
Cable outlet thread 20mmX1.5mm free conversion G1 / 2 opcional
Dimensiones (190X160X110) mm
Shell material: die-cast aluminum
Peso 1Kg
Advantages a prueba de polvo, explosión, corrosion-proof