Description
OT600 portable pump suction type 6 in1 gas detector is a kind of intrinsically safe instrument that can continuously detect the concentration of various gases. It can combine up to 7 kinds of gas under test, and the gas under test can be combined at any time as needed.It is applicable to gas leakage and emergency, underground pipeline and other places in explosion-proof places, which can effectively ensure the life safety of workers from being harmed and production equipment from being damaged.
OT600 portable pump suction type 6 in1 gas detector adopts the principle of pump suction (freely converted natural diffusion) detection. The sensor adopts imported components, with excellent sensitivity and excellent repeatability.The instrument adopts embedded microcomputer control and simple operation. The detector shell is made of high strength engineering plastic and compound anti-skid rubber.
Functions Features
- Advanced sensor intelligent module technology, sensor exchange at will
- The inspection specification type is detailed in the attached form
- The overhaul USES a 2.4-inch high-definition full-color IPS industrial screen
- The solubility test shows various technical indicators and gas concentration values
- Throughout PPM, %VOL, mg3/m3, mg/L concentration units can be switched freely
- The aspect capsid USES a high IP coating process
- High performance imported sensor
Technical Parameters
Detect method | Pump suction (manual switch to natural diffusion) |
Throughout the spectrum of sensors | Catalysis, electrochemistry, PID, infrared |
Inspection gas | see the attached table of parameters |
Response time | <30s |
Indication error | 5%FS |
Display method | The LCD displays real-time data and system state, light-emitting diode, sound, vibration indicating alarm, failure and underpressure |
Working conditions | Temperature: – 20 ℃ to 50 ℃; Humidity: < 95%RH without condensation |
Charged voltage | DC3.6V lithium battery;4000 mah |
Charge time | < 6h |
Extended working hours | 8h consecutive (non-alarm status); |
sensor life | 2 years |
Explosion protection type | intrinsically safe type |
The upload interface | U3 data port |
Sensor protection | comes with a built-in switching device |
Shell material | frosted rubber |
Disciplinary anti-explosion sign | Ex ib IIB T3 Gb |
protection grade | IP65 |
Dimensions | 165mm * 80mm * 42mm |
weight | About 300g |
Common Gas Parameter listing | ||||
Gas detected | Measuring Range | Optional Range | Resolution Rat | Response Time |
LEL -combustible gas | 0-100%LEL | 0-100%VOL(Infrared or catalytic ) | 1%LEL/1%vol | ≤10s |
carbon monoxide | 0-1000PPm | 0-500/2000/5000PPm | 0.1/1PPm | ≤10s |
TVOC | 0-100PPM | 0-100PPM | 0.1PPm/1PPM | ≤15s |
hydrogen | 0-100%LEL | 0-1000PPM | 1%LEL/1PPM | ≤15s |
natural gas | 0-100%LEL | 0-100%LEL | 1%LEL | ≤10s |
Oxygen-O2 | 0-30%VOL | 0-30%、0-100%VOL | 0.1%vol | ≤10s |
ozone | 0-10PPm | 0-20、100PPm | 0.01PPm/0.1PPM | ≤15s |
hydrogen sulfide-H2S | 0-100PPm | 0-50、200、1000PPm | 1/0.1PPm | ≤10s |
Methane-CH4 | 0-100%LEL | 0-100%VOL | 1%LEL/1%vol | ≤10s |
fluorine | 0-10PM | 0-1、10PPM | 1/0.1PPm | ≤15s |
hydrogen chloride | 0-20PPm | 0-20/50PPm/100PPM | 0.01/0.1PPm | ≤15s |
Nitrogen-N2 | 0-30%VOL | 0-30%VOL、100%VOL | 0.1%LEL/1PPM | ≤10s |
hydrogen | 0-100%LEL | 0-1000PPm | 1%LEL/0.1PPm | ≤15s |
chlorine | 0-20PPm | 0-10、100PPm | 0.1PPm | ≤15s |
ammonia gas | 0-100PPm | 0-50、500、1000PPm | 1/0.1PPm | ≤15s |
oxynitride | 0-20PPm | 0-50、1000PPm | 0.1/1PPm | ≤15s |
methanal | 0-20PPm | 0-50、100PPm | 1/0.1PPm | ≤15s |
sulfur dioxide | 0-20PPm | 0-50、1000PPm | 0.1/1PPm | ≤15s |
nitric oxide | 0-250PPm | 0-500、1000PPm | 1PPm | ≤15s |
nitrogen dioxide | 0-20PPm | 0-50、1000PPm | 0.1/1PPm | ≤15s |
phosphine | 0-20PPm | 0-20、100PPm | 0.1PPm | ≤15s |
acrylonitrile | 0-100PPM | 0-100PPm | 0.1/1PPm | ≤15s |
carbon dioxide | 0-5000PPm | 0-1%/5%/10%VOL(Infrared ) | 1PPM/0.01%VOL | ≤15s |
hydrogen fluoride | 0-10PPm | 0-1、10、50、100PPM | 0.01/0.1PPm | ≤15s |
Xylene/methylbenzene | 0-20PPm | 0-5、10、50、100PPm | 0.01/0.1PPm | ≤15s |
oxirane | 0-100PPm | 0-100PPm | 1/0.1PPm | ≤15s |
For other gases and measuring ranges, please contact us directly! |