Тел.: +86 16692113216 Электронная почта:запрос@otywell-safety.com

О Контакт |

Промышленный датчик кислорода R-4OX - Отивелл | Производитель детекторов газа

Промышленный датчик газа/

Промышленный датчик кислорода R-4OX

Long Term Output Drift< 5% per annum
Recommended Storage Temp0℃to 20℃
Expected Operating Life> 24 months in air
Standard Warranty24 months from date of dispatch

 

ЯРЛЫК: otywell gas sensorO2 sensorH2S sensorCO sensorNH3 sensor

Электронная почта:запрос@otywell-safety.com

Мобильная связь/WhatsAPP:+8616692113216

  • Product Details

Описание

The R-40X electrochemical oxygen sensor utilizes the electro-chemical activity of the gas under measurement to undergo elec-trochemical oxidation or reaction inside it, thereby converting the content of the gas under measurement into a current (or voltage) signal output to distinguish the composition and concentration of the gas.

Функции Особенности

  • Good stability
  • High precision
  • Fast response speed
  • Anti-cross interference
  • Linear optimization
  • Strong adaptability

Технические параметры

Lifetime Details

Long Term Output Drift< 5% per annum
Recommended Storage Temp0℃to 20℃
Expected Operating Life> 24 months in air
Standard Warranty24 months from date of dispatch

 

Intrinsic Safety Data

Maximum current in normal operation (pure O2)0.01 A
Maximum o/c Voltage (10 to 100% О2)0.9 В
Maximum s/c Current (10 to 100% О2)0.5 A

 

Erformance Characteristics

Output signal0.10 ± 0.03 mA
Zero Current (Offset)< 0.6% vol. О2
T90 Response Time< 15 секунды
Measurement Range0 – 25% Oxygen
Maximum Overload30% Oxygen
LinearityLinear
Recommended Load Resistor100 ohms

 

Environmental Details

Temperature Range Continuous-30℃to +50℃
Pressure Range800 to 1200 mbar
Operating Humidity Range5% to 95% правая рука

Toxic gases at TLV levels will have no cross-sensitivity effect on oxygen sensors. At very high levels (i.e. percent levels), highly oxidising gases (e.g. ozone, chlorine) will interfere to the extent of their oxygen equivalent, but most other commonly occurring gases will have no effect.

Important Note:

Acid gases such as CO2 and SO2 will be absorbed by the electrolyte and tend to increase the flux of oxygen to the electrode. This gives an enhanced oxygen signal of approximately 0.3% of signal per 1% CO2.Oxygen sensors are not suitable for continuous operation in concentrations of CO2 above 25%.
All performance data is based on conditions at 20℃, 50%RH and 1 atm, using recommended circuitry.
Sensor performance is temperature dependent, and please Contact us for temperature performance other than 20℃.

 

ЯРЛЫК: otywell gas sensorO2 sensorH2S sensorCO sensor

 

Электронная почта:запрос@otywell-safety.com

Мобильная связь/WhatsAPP:+8616692113216

Note: Not all gases and range are listed, if you need more information, please contact us.

Common Gas Parameter listing
Gas detectedMeasuring RangeOptional RangeResolution RatResponse Time
LEL -combustible gas0-100%ЛЭЛ0-100%VOL(Infrared or catalytic )1%LEL/1%vol≤10s
carbon monoxide0-1000PPm0-500/2000/5000PPm0.1/1PPm≤10s
ТВОС0-100ППМ0-100ППМ0.1PPm/1PPM≤15s
hydrogen0-100%ЛЭЛ0-1000ППМ1%LEL/1PPM≤15s
природный газ0-100%ЛЭЛ0-100%ЛЭЛ1%ЛЭЛ≤10s
Oxygen-O20-30%ОБЪЕМ0-30%、0-100%ОБЪЕМ0.1%vol≤10s
ozone0-10PPm0-20、100PPm0.01PPm/0.1PPM≤15s
hydrogen sulfide-H2S0-100PPm0-50、200、1000PPm1/0.1PPm≤10s
Methane-CH40-100%ЛЭЛ0-100%ОБЪЕМ1%LEL/1%vol≤10s
fluorine0-10PM0-1、10ППМ1/0.1PPm≤15s
hydrogen chloride0-20PPm0-20/50PPm/100PPM0.01/0.1PPm≤15s
Nitrogen-N20-30%ОБЪЕМ0-30%ОБЪЕМ、100%ОБЪЕМ0.1%LEL/1PPM≤10s
hydrogen0-100%ЛЭЛ0-1000PPm1%LEL/0.1PPm≤15s
chlorine0-20PPm0-10、100PPm0.1PPm≤15s
ammonia gas0-100PPm0-50、500、1000PPm1/0.1PPm≤15s
oxynitride0-20PPm0-50、1000PPm0.1/1PPm≤15s
methanal0-20PPm0-50、100PPm1/0.1PPm≤15s
sulfur dioxide0-20PPm0-50、1000PPm0.1/1PPm≤15s
nitric oxide0-250PPm0-500、1000PPm1PPm≤15s
nitrogen dioxide0-20PPm0-50、1000PPm0.1/1PPm≤15s
phosphine0-20PPm0-20、100PPm0.1PPm≤15s
acrylonitrile0-100ППМ0-100PPm0.1/1PPm≤15s
carbon dioxide0-5000PPm0-1%/5%/10%ОБЪЕМ(Infrared )1частей на миллион/0,01% об.≤15s
hydrogen fluoride0-10PPm0-1、10、50、100ППМ0.01/0.1PPm≤15s
Xylene/methylbenzene0-20PPm0-5、10、50、100PPm0.01/0.1PPm≤15s
oxirane0-100PPm0-100PPm1/0.1PPm≤15s
For other gases and measuring ranges, please contact us directly!

Note: Not all gases and range are listed, if you need more information, please contact us.

 

ЯРЛЫК: otywell gas sensorO2 sensorH2S sensorCO sensor

 

Электронная почта:запрос@otywell-safety.com

Мобильная связь/WhatsAPP:+8616692113216

Предыдущий:

Следующий:

Расследование

    ПерсональныйБизнесРаспределитель

    Оставить сообщение