Despre Contact |

Senzor de oxigen industrial R-4OX - Otywell | Producator de detectoare de gaz

Senzor de gaz din industrie/

Senzor de oxigen industrial R-4OX

Long Term Output Drift< 5% per annum
Recommended Storage Temp0℃to 20℃
Expected Operating Life> 24 months in air
Standard Warranty24 months from date of dispatch

 

TAG: otywell gas sensorO2 sensorH2S sensorCO sensorNH3 sensor

E-mail:inquiry@otywell-safety.com

Mobile/WhatsApp:+8616692113216

  • Product Details

Descriere

The R-40X electrochemical oxygen sensor utilizes the electro-chemical activity of the gas under measurement to undergo elec-trochemical oxidation or reaction inside it, thereby converting the content of the gas under measurement into a current (or voltage) signal output to distinguish the composition and concentration of the gas.

Funcții Caracteristici

  • Good stability
  • High precision
  • Fast response speed
  • Anti-cross interference
  • Linear optimization
  • Strong adaptability

Parametrii tehnici

Lifetime Details

Long Term Output Drift< 5% per annum
Recommended Storage Temp0℃to 20℃
Expected Operating Life> 24 months in air
Standard Warranty24 months from date of dispatch

 

Intrinsic Safety Data

Maximum current in normal operation (pure O2)0.01 A
Maximum o/c Voltage (10 to 100% O2)0.9 V
Maximum s/c Current (10 to 100% O2)0.5 A

 

Erformance Characteristics

Semnal de ieșire0.10 ± 0.03 mA
Zero Current (Offset)< 0.6% vol. O2
T90 Response Time< 15 seconds
Measurement Range0 – 25% Oxygen
Maximum Overload30% Oxygen
LinearityLinear
Recommended Load Resistor100 ohms

 

Environmental Details

Temperature Range Continuous-30℃to +50℃
Pressure Range800 to 1200 mbar
Operating Humidity Range5% to 95% RH

Toxic gases at TLV levels will have no cross-sensitivity effect on oxygen sensors. At very high levels (i.e. percent levels), highly oxidising gases (e.g. ozone, chlorine) will interfere to the extent of their oxygen equivalent, but most other commonly occurring gases will have no effect.

Important Note:

Acid gases such as CO2 and SO2 will be absorbed by the electrolyte and tend to increase the flux of oxygen to the electrode. This gives an enhanced oxygen signal of approximately 0.3% of signal per 1% CO2.Oxygen sensors are not suitable for continuous operation in concentrations of CO2 above 25%.
All performance data is based on conditions at 20℃, 50%RH and 1 atm, using recommended circuitry.
Sensor performance is temperature dependent, and please Contact us for temperature performance other than 20℃.

 

TAG: otywell gas sensorO2 sensorH2S sensorCO sensor

 

E-mail:inquiry@otywell-safety.com

Mobile/WhatsApp:+8616692113216

Nota: Not all gases and range are listed, if you need more information, please contact us.

Common Gas Parameter listing
Gas detectedMeasuring RangeOptional RangeResolution RatTimp de răspuns
LEL -combustible gas0-100%LEL0-100%VOL(Infrared or catalytic )1%LEL/1%vol≤10s
monoxid de carbon0-1000PPm0-500/2000/5000PPm0.1/1PPm≤10s
TVOC0-100PPM0-100PPM0.1PPm/1PPM≤15s
hydrogen0-100%LEL0-1000PPM1%LEL/1PPM≤15s
gaz natural0-100%LEL0-100%LEL1%LEL≤10s
Oxygen-O20-30%VOL0-30%、0-100%VOL0.1%vol≤10s
ozone0-10PPm0-20、100PPm0.01PPm/0.1PPM≤15s
hydrogen sulfide-H2S0-100PPm0-50、200、1000PPm1/0.1PPm≤10s
Methane-CH40-100%LEL0-100%VOL1%LEL/1%vol≤10s
fluorine0-10PM0-1、10PPM1/0.1PPm≤15s
hydrogen chloride0-20PPm0-20/50PPm/100PPM0.01/0.1PPm≤15s
Nitrogen-N20-30%VOL0-30%VOL、100%VOL0.1%LEL/1PPM≤10s
hydrogen0-100%LEL0-1000PPm1%LEL/0.1PPm≤15s
chlorine0-20PPm0-10、100PPm0.1PPm≤15s
ammonia gas0-100PPm0-50、500、1000PPm1/0.1PPm≤15s
oxynitride0-20PPm0-50、1000PPm0.1/1PPm≤15s
methanal0-20PPm0-50、100PPm1/0.1PPm≤15s
sulfur dioxide0-20PPm0-50、1000PPm0.1/1PPm≤15s
nitric oxide0-250PPm0-500、1000PPm1PPm≤15s
nitrogen dioxide0-20PPm0-50、1000PPm0.1/1PPm≤15s
phosphine0-20PPm0-20、100PPm0.1PPm≤15s
acrylonitrile0-100PPM0-100PPm0.1/1PPm≤15s
carbon dioxide0-5000PPm0-1%/5%/10%VOL(Infrared )1PPM/0.01%VOL≤15s
hydrogen fluoride0-10PPm0-1、10、50、100PPM0.01/0.1PPm≤15s
Xylene/methylbenzene0-20PPm0-5、10、50、100PPm0.01/0.1PPm≤15s
oxirane0-100PPm0-100PPm1/0.1PPm≤15s
For other gases and measuring ranges, please contact us directly!

Nota: Not all gases and range are listed, if you need more information, please contact us.

 

TAG: otywell gas sensorO2 sensorH2S sensorCO sensor

 

E-mail:inquiry@otywell-safety.com

Mobile/WhatsApp:+8616692113216

Prev:

Următorul:

Anchetă

    PersonalBusinessDistributor

    Lasă un mesaj