Rilevatore di gas fisso/

GTYQ-TCB4-ZX INDUSTRIALE E COMMERCIALE DETTAGLIO DI GAS COMBUSTIBILE

Detection gas:flammable, ossigeno, toxic gas, VOC (see attached table)

Metodo di rilevamento:diffusione naturale

Metodo di visualizzazione:LED digital display

Working power supply:DC24V/DC36V (two buses)

Tempo di risposta:flammable <30S; tossico <60S

Environmental temperature:(-40~70)℃ (flammable); (-20~40)℃ (tossico)

Umidità relativa:≤93%RH

Environmental pressure:(86~106)KPa

Marchio antideflagrante:Ex d IIC T6 Gb; Ex tD A21 IP66 T80℃

Numero del certificato antideflagrante:CE21.1021

Livello di protezione:IP66

Measurement number:2018C239-41

Connecting cable:RVVP 3×1.5mm2; RVVP 4×1.5mm2; RVVP 2x2.5mm2

Transmission distance:≤1000m

Dimensioni del prodotto:(131X150X109)mm

  • Dettagli del prodotto

Descrizione

GT-TCB4 industrial and commercial point-type combustible gas detector is a new type of gas leak detection instrument produced by our company. Its outstanding feature is that it uses high-performance imported catalytic combustion, electrochemical, infrared dual-beam gas sensors, combined with sophisticated SMD technology, and has good repeatability and resistance to moisture and temperature interference, long service life, and easy operation. It is suitable for gas leakage concentration detection in various industrial environments.

GT-TCB4 industrial and commercial point-type combustible gas detector can convert the leakage gas concentration signal in the air into an electrical signal output for remote transmission, and the monitoring instrument or controller host can view the detection results away from the site.

Parametri tecnici

Detection gas: flammable, ossigeno, toxic gas, VOC (see attached table)

Metodo di rilevamento: diffusione naturale

Metodo di visualizzazione: LED digital display

Working power supply: DC24V/DC36V (two buses)

Tempo di risposta: flammable <30S; tossico <60S

Environmental temperature: (-40~70)℃ (flammable); (-20~40)℃ (tossico)

Umidità relativa: ≤93%RH

Environmental pressure: (86~106)KPa

Marchio antideflagrante: Ex d IIC T6 Gb; Ex tD A21 IP66 T80℃

Numero del certificato antideflagrante: CE21.1021

Livello di protezione: IP66

Measurement number: 2018C239-41

Connecting cable: RVVP 3×1.5mm2; RVVP 4×1.5mm2; RVVP 2×2.5mm2

Transmission distance: ≤1000m

Dimensioni del prodotto: (131X150X109)mm