Capteur de méthane laser

  • High Precision
  • Miniaturization
  • Long Service Life
  • Long Effective Absorption Path
  • High Reliability
  • Anti-interference
  • 3.3V ~ 5.0V Operating Voltage
  • Quadruple Protection

 

ÉTIQUETER: otywell gas sensor,Capteur de méthane laser, O2 sensorH2S sensorCO sensor,PID sensor,voc sensor

E-mail:enquête@otywell-safety.com

Mobile / whatsapp:+8616692113216

  • Détails du produit

Description

The laser methane telemetry optical component uses tunable laser spectral absorption (TDLAS) technology to accurately measure the target gas. The laser and detector integrated in the telemetry optical component realize high-precision, high-density, and high-reliability miniaturized integrated packaging; the telemetry optical component adopts an excellent optical system to achieve the lowest (optical noise) while maximizing the signal-to-noise ratio, ensuring the advantages of high telemetry accuracy and fast response of the telemeter. It can match most of the handheld laser methane telemeters and telemetry pan/tilts on the current market.

Fonctions fonctionnalités

  • High Precision
  • Miniaturization
  • Long Service Life
  • Long Effective Absorption Path
  • High Reliability
  • Anti-interference
  • 3.3V ~ 5.0V Operating Voltage
  • Quadruple Protection
Long Effective Absorption Optical Path
Long Effective Absorption Path Is Realized In A Small Optical System

 

ÉTIQUETER: otywell gas sensor,Capteur de méthane laser, O2 sensorH2S sensorCO sensor,PID sensor,voc sensor

E-mail:enquête@otywell-safety.com

Mobile / whatsapp:+8616692113216

 

Anti-interference
High Reliability | Strong Anti-interference(Non-methane Gas Does Not React)

Suitable For High Humidity Environment

Long Service Life
The Service Life Of The Product Can Reach 10 Years

 

Quadruple Protection
Étanche | Étanche à la poussière

À l'épreuve des explosions | Ems Protection

 

Paramètres techniques

 

argument

Minimum value Typical value Maximum value unité
Conventional parameter
Température de stockage -40 85
Température de fonctionnement -40 60(70)
Humidité de fonctionnement (sans condensation) 98 %RH
Pression de travail 80 116 kPa
Plage de mesure 0 100 %Lel
Basic error Normal temperature and pressure ±3%LEL
Overall condition ±7%LEL
Temps de réponse 15 s
Minimum resolution 0.01 %Vol
Communication interface
TTL Baud rate 115200 baud
Stop bit 1 Bit
Data bit 8 Bit
Check bit Bit
Flow control bit Bit
Electrical performance (room temperature)
Tension de fonctionnement 3.3 3.6 5 V
Operating current (average) 30 mA
Operating current (instantaneous) 250 320 mA

 

Note: Tous les gaz et cuisinières ne sont pas répertoriés, si vous avez besoin de plus d'informations, veuillez nous contacter.

 