Description
The JB-TB-GDB18 combustible gas alarm controller is a multi-point monitoring gas alarm controller developed by our company. It is used to detect the concentration of the gas to be tested in the ambient air. It can be equipped with multiple detectors for detecting different gas components and simultaneously monitor multiple points centrally. This product also has four-bus, three-wire and two-bus interfaces, which can meet the use of detectors with various wiring methods.
This system uses a microprocessor as a control unit and a high-precision sensor as a detection component, with high sensitivity and fast response speed. When the concentration of the gas to be tested is detected in the environment and reaches or exceeds the warning alarm value, the controller immediately issues an audible and visual alarm to remind us to take safety measures in time, and starts the execution control unit to control the drive exhaust or other peripheral equipment to prevent poisoning accidents, explosions and fires, thereby ensuring the safety of life and property.
Fonctions fonctionnalités
◆ LCD Chinese display, simple and clear
◆ The product has a built-in microprocessor and rich software functions to complete transmitter signal sampling, real-time data calculation, system fault detection, power management, alarm display, alarm peripheral driver and other functions
◆ Intelligent system: convenient online zero point correction
◆ Multi-channel passive relay contact output
◆ Simple installation, fix the mounting bracket on the wall, hang the controller to complete the installation
Paramètres techniques
- Méthode d'installation: Indoor wall-mounted
- Temps de réponse: ≤30s
- Indication method: Écran LCD, alarme sonore et lumineuse
- Working environment temperature: -10℃~+50℃
- Working environment humidity: ≤93%RH
- Main power supply: AC220V+15%, 50Hz+1%
- No-load power: ≤10W
- Detector power supply voltage: DC24V±10%
- Backup power undervoltage alarm value: DC21V±1V
- Dimensions: L295 mmxW226 mmxH86 mm
- Poids du produit: about 3.95kg
- Cable requirements: 2RVVP4x1.5mm2 (four-bus),≥RVVP 3×1.5mm2 (three-wire),≥RVVP 2×1.5mm2 (two buses)
- Communication distance between detector and host: ≤1000m
- Number of channels of this machine: 4 buses: 1 channel: 3 lines: 12 channels:2 buses: 2 channels;
- Control output contacts: 2 groups of passive switches: 1 group of 24V pulse signals:1 group of AC220V pulse signals
- Signal de sortie: RS485, (4~20)mA.
Point-type combustible gas detector with two bus signals
Note: Tous les gaz et cuisinières ne sont pas répertoriés, si vous avez besoin de plus d'informations, veuillez nous contacter.
| Liste des paramètres de gaz commun | ||||
| Gaz détecté | Plage de mesures | Plage facultative | Rat de résolution | Temps de réponse |
| Gaz combustible lel | 0-100%Lel | 0-100%Vol (infrarouge ou catalytique) | 1%Lel / 1% vol | ≤10s |
| monoxyde de carbone | 0-1000Ppm | 0-500/2000/5000Ppm | 0.1/1Ppm | ≤10s |
| Tvoc | 0-100Ppm | 0-100Ppm | 0.1Ppm / 1 ppm | ≤15s |
| hydrogène | 0-100%Lel | 0-1000Ppm | 1%Lel / 1 ppm | ≤15s |
| gaz naturel | 0-100%Lel | 0-100%Lel | 1%Lel | ≤10s |
| Oxygène-o2 | 0-30%Vol | 0-30%、0-100%Vol | 0.1%vol | ≤10s |
| ozone | 0-10Ppm | 0-20、100Ppm | 0.01Ppm / 0,1 ppm | ≤15s |
| hydrogène sulfure-H2S | 0-100Ppm | 0-50、200、1000Ppm | 1/0.1Ppm | ≤10s |
| Méthane-ch4 | 0-100%Lel | 0-100%Vol | 1%Lel / 1% vol | ≤10s |
| fluor | 0-10PM | 0-1、10Ppm | 1/0.1Ppm | ≤15s |
| chlorure d'hydrogène | 0-20Ppm | 0-20/50Ppm / 100 ppm | 0.01/0.1Ppm | ≤15s |
| Azote-n2 | 0-30%Vol | 0-30%Vol、100%Vol | 0.1%Lel / 1 ppm | ≤10s |
| hydrogène | 0-100%Lel | 0-1000Ppm | 1%Lel / 0,1 ppm | ≤15s |
| chlore | 0-20Ppm | 0-10、100Ppm | 0.1Ppm | ≤15s |
| gaz d'ammoniac | 0-100Ppm | 0-50、500、1000Ppm | 1/0.1Ppm | ≤15s |
| oxynitride | 0-20Ppm | 0-50、1000Ppm | 0.1/1Ppm | ≤15s |
| méthanal | 0-20Ppm | 0-50、100Ppm | 1/0.1Ppm | ≤15s |
| dioxyde de soufre | 0-20Ppm | 0-50、1000Ppm | 0.1/1Ppm | ≤15s |
| oxyde nitrique | 0-250Ppm | 0-500、1000Ppm | 1Ppm | ≤15s |
| dioxyde d'azote | 0-20Ppm | 0-50、1000Ppm | 0.1/1Ppm | ≤15s |
| phosphine | 0-20Ppm | 0-20、100Ppm | 0.1Ppm | ≤15s |
| acrylonitrile | 0-100Ppm | 0-100Ppm | 0.1/1Ppm | ≤15s |
| dioxyde de carbone | 0-5000Ppm | 0-1%/5%/10%Vol(Infrarouge ) | 1Ppm / 0,01% vol | ≤15s |
| fluorure d'hydrogène | 0-10Ppm | 0-1、10、50、100Ppm | 0.01/0.1Ppm | ≤15s |
| Xylène / méthylbenzène | 0-20Ppm | 0-5、10、50、100Ppm | 0.01/0.1Ppm | ≤15s |
| oxirane | 0-100Ppm | 0-100Ppm | 1/0.1Ppm | ≤15s |
| Pour les autres gaz et les gammes de mesures, Veuillez nous contacter directement! | ||||
Note: Tous les gaz et cuisinières ne sont pas répertoriés, si vous avez besoin de plus d'informations, veuillez nous contacter.