Description
GDB11 gas alarm controller mainly receives the detection data of on-site gas detectors. When the preset alarm value is reached or exceeded, it will immediately send out sound and light alarms to remind the safety personnel to take safety measures in time. At the same time, it will automatically start the on-site fan or cut off the gas source to prevent poisoning/explosion and fire, thereby protecting the lives of personnel and the property safety of enterprises.
Fonctions fonctionnalités
★Chinese key operation
★High and low alarm points can be freely set
★Built-in sound and light alarm lamp
★Switch output for -way alarm control
★With password management function, important operations require password verification
★Two sets of pulse relay signal output
★Time management and display function
ÉTIQUETER: otywell gas control panel gas control panel OEM
E-mail:enquête@otywell-safety.com
Mobile / whatsapp:+8616692113216
Paramètres techniques
★Display mode: digital tube display
★Working power supply: AC220V+10%
★Installation method: on-site fixed installation, wall-mounted
★Networking capacity: 2-way RS485/4-20mA signal input
★Alarm mode: alarme sonore et lumineuse
★Alarm point: two-level alarm, can be freely set by the user
★Power supply voltage: AC220V+10% 50HZ
★Relay capacity: 3UN
★Working temperature: (0~50)°C
★Relative humidity: (20~93)%RH
★Storage temperature: (-10~ 50)°C
★Pressure range: (86~ 106)KPa
★Cable requirements: Bus: RVVP 4×1.5mm2
★Transmission distance: ≤1 500m
Note: Tous les gaz et cuisinières ne sont pas répertoriés, si vous avez besoin de plus d'informations, veuillez nous contacter.
| Liste des paramètres de gaz commun | ||||
| Gaz détecté | Plage de mesures | Plage facultative | Rat de résolution | Temps de réponse |
| Gaz combustible lel | 0-100%Lel | 0-100%Vol (infrarouge ou catalytique) | 1%Lel / 1% vol | ≤10s |
| monoxyde de carbone | 0-1000Ppm | 0-500/2000/5000Ppm | 0.1/1Ppm | ≤10s |
| Tvoc | 0-100Ppm | 0-100Ppm | 0.1Ppm / 1 ppm | ≤15s |
| hydrogène | 0-100%Lel | 0-1000Ppm | 1%Lel / 1 ppm | ≤15s |
| gaz naturel | 0-100%Lel | 0-100%Lel | 1%Lel | ≤10s |
| Oxygène-o2 | 0-30%Vol | 0-30%、0-100%Vol | 0.1%vol | ≤10s |
| ozone | 0-10Ppm | 0-20、100Ppm | 0.01Ppm / 0,1 ppm | ≤15s |
| hydrogène sulfure-H2S | 0-100Ppm | 0-50、200、1000Ppm | 1/0.1Ppm | ≤10s |
| Méthane-ch4 | 0-100%Lel | 0-100%Vol | 1%Lel / 1% vol | ≤10s |
| fluor | 0-10PM | 0-1、10Ppm | 1/0.1Ppm | ≤15s |
| chlorure d'hydrogène | 0-20Ppm | 0-20/50Ppm / 100 ppm | 0.01/0.1Ppm | ≤15s |
| Azote-n2 | 0-30%Vol | 0-30%Vol、100%Vol | 0.1%Lel / 1 ppm | ≤10s |
| hydrogène | 0-100%Lel | 0-1000Ppm | 1%Lel / 0,1 ppm | ≤15s |
| chlore | 0-20Ppm | 0-10、100Ppm | 0.1Ppm | ≤15s |
| gaz d'ammoniac | 0-100Ppm | 0-50、500、1000Ppm | 1/0.1Ppm | ≤15s |
| oxynitride | 0-20Ppm | 0-50、1000Ppm | 0.1/1Ppm | ≤15s |
| méthanal | 0-20Ppm | 0-50、100Ppm | 1/0.1Ppm | ≤15s |
| dioxyde de soufre | 0-20Ppm | 0-50、1000Ppm | 0.1/1Ppm | ≤15s |
| oxyde nitrique | 0-250Ppm | 0-500、1000Ppm | 1Ppm | ≤15s |
| dioxyde d'azote | 0-20Ppm | 0-50、1000Ppm | 0.1/1Ppm | ≤15s |
| phosphine | 0-20Ppm | 0-20、100Ppm | 0.1Ppm | ≤15s |
| acrylonitrile | 0-100Ppm | 0-100Ppm | 0.1/1Ppm | ≤15s |
| dioxyde de carbone | 0-5000Ppm | 0-1%/5%/10%Vol(Infrarouge ) | 1Ppm / 0,01% vol | ≤15s |
| fluorure d'hydrogène | 0-10Ppm | 0-1、10、50、100Ppm | 0.01/0.1Ppm | ≤15s |
| Xylène / méthylbenzène | 0-20Ppm | 0-5、10、50、100Ppm | 0.01/0.1Ppm | ≤15s |
| oxirane | 0-100Ppm | 0-100Ppm | 1/0.1Ppm | ≤15s |
| Pour les autres gaz et les gammes de mesures, Veuillez nous contacter directement! | ||||
Note: Tous les gaz et cuisinières ne sont pas répertoriés, si vous avez besoin de plus d'informations, veuillez nous contacter.
ÉTIQUETER: otywell gas control panel gas control panel OEM
E-mail:enquête@otywell-safety.com
Mobile / whatsapp:+8616692113216
Otywell | Fabricant de détecteurs de gaz







Wechat
Scannez le code QR avec WeChat