Tel: +86-13333857585 Correo electrónico: consulty@otywell-detector.com

Acerca de Contacto |

Detector de llama de doble espectro S600EX-IR2-UV (Dual IR, UV único) - Otywell | Fabricante de analizador de gas

Detector de llamas/

Detector de llama de doble espectro S600EX-IR2-UV (Dual IR, UV único)

Response spectral range4.4μm, 3.8μm, 185-260Nuevo Méjico

Tiempo de respuesta:6s

Viewing angle range≤110 °

Detection distanceClase I

Temperatura ambiente:-10 ~ 55 ℃

Environmental humidity≤95% RH

Pressure range86 ~ 106Kpa

Working voltageDc24v

Working currentcurrent≤25mA, alarm current≤35mA

Executive standardGB15631-2008, GB12791-2006

Explosion-proof gradeEx d ⅱc t6 gb

Protection gradeIP66

Signal outputSwitching relay contact output, RS-485 (built-in DIP switch, can set the address of the detector)

Installation methodwall or ceiling

Cable outlet thread20mmX1.5mm free conversion G1 / 2 opcional

Dimensiones:(190X160X110) mm

Shell materialdie-cast aluminum

Peso:1Kg

Advantagesa prueba de polvo, explosión, corrosion-proof

  • Detalles del producto

Descripción

S600-ExIR2-UV point type infrared / UV flame detector contains two infrared wavelength sensors and a highly sensitive imported UV/ultraviolet sensor and optical filter. The ultraviolet sensor can respond to ultraviolet radiation at the moment of fire and explosive ignition. The other two infrared sensors, one has the highest sensitivity to the CO2 emission spectrum (4.4μm), and the other interferes with ambient light and heat radiation For detection, the detector makes a composite judgment on the ultraviolet and infrared signals generated in the event of a fire, and performs multi-signal processing in conjunction with the logical comprehensive judgment of the flame flicker frequency to minimize false alarms and the best fire detection performance required. The flame detector has an early warning function for the fire of organic materials such as hydrocarbons and the fire of inorganic materials.

Funciones de funciones

Parámetros técnicos

Response spectral range 4.4μm, 3.8μm, 185-260Nuevo Méjico
Tiempo de respuesta 6s
Viewing angle range ≤110 °
Detection distance Clase I
Temperatura ambiente -10 ~ 55 ℃
Environmental humidity ≤95% RH
Pressure range 86 ~ 106Kpa
Working voltage Dc24v
Working current current≤25mA, alarm current≤35mA
Executive standard GB15631-2008, GB12791-2006
Explosion-proof grade Ex d ⅱc t6 gb
Protection grade IP66
Signal output Switching relay contact output, RS-485 (built-in DIP switch, can set the address of the detector)
Installation method wall or ceiling
Cable outlet thread 20mmX1.5mm free conversion G1 / 2 opcional
Dimensiones (190X160X110) mm
Shell material die-cast aluminum
Peso 1Kg
Advantages a prueba de polvo, explosión, corrosion-proof

Previsamente:

Deja una respuesta

Dejar un mensaje