Tel: +86-13333857585 Correo electrónico: consulty@otywell-detector.com

Acerca de Contacto |

Sensor de gas monóxido de carbono - Otywell | Fabricante de analizador de gas

Sensor de gas de la industria/

Sensor de gas monóxido de carbono

Señal de salida70 ± 250 nA / ppm
Typical Baseline Range (pure air)≥±2 ppm CO equivalent
Fiter Capacity﹥2000 ppm hours
T90 Response Time< 30 artículos de segunda clase

  • Detalles del producto

Descripción

Electrochemical Carbon monoxide gas sensor utilizes the electro-chemical activity of the gas under measurement to undergo elec-trochemical oxidation or reaction inside it, thereby converting the content of the gas under measurement into a current (or voltage) signal output to distinguish the composition and concentration of the gas.

Funciones de funciones

  • Fast response and recovery time
  • High stability
  • Robust at humidity and temperature extremes
  • Meets sensor requirements outined in: AQ6205-2006 and EN5544

Parámetros técnicos

Performance Characte ristics
Señal de salida70 ± 250 nA / ppm
Typical Baseline Range (pure air)≥±2 ppm CO equivalent
Fiter Capacity﹥2000 ppm hours
T90 Response Time< 30 artículos de segunda clase
Rango de medición0 – 2000 ppm
Maximum Overload5000 ppm
LinearityLinear up 2000ppm
Repeatability< ±2% CO equivalent
Recommended Load Resistor10 ohms
Resolución (Electronics dependent)< 0.5 ppm typical
Ambiental
Temperature Range Continuous-30oC to +50oC
Rango de presión800 to 1200 mbar
Operating Humidity Range15% to 90% RH
Lifetime
Long Term Output Drift< 5% per annum
Recommended Storage Temp0oC to 20oC
Expected Operating Life> 24 months in air
Standard Warranty24 months from date of dispatch
Intrinsic Safety Da ta
Maximum at 2000 ppm0.3 mA
Maximum o/c Voltage1.3 V
Maximum s/c Current<1.0 A

Previsamente: