هاتف: +86-13333857585 بريد إلكتروني: requiry@otywell-ntector.com

عن اتصال |

S600EX-IR2-UV كاشف اللهب المزدوج (ثنائي الأشعة تحت الحمراء, UV واحد) - أوتيويل | مصنع محلل الغاز

كاشف اللهب/

S600EX-IR2-UV كاشف اللهب المزدوج (ثنائي الأشعة تحت الحمراء, UV واحد)

Response spectral range4.4μm, 3.8μm, 185-260nm

Response time6s

Viewing angle range≤110 °

Detection distanceClass I

Ambient temperature-10 ~ 55

Environmental humidity≤95% RH

Pressure range86 ~ 106Kpa

جهد العمل:DC24V

Working currentcurrent≤25mA, alarm current≤35mA

Executive standardGB15631-2008, GB12791-2006

Explosion-proof gradeEX d ⅡC T6 Gb

Protection gradeIP66

Signal outputSwitching relay contact output, RS-485 (built-in DIP switch, can set the address of the detector)

Installation methodwall or ceiling

Cable outlet thread20mmX1.5mm free conversion G1 / 2 خياري

Dimensions(190X160X110) mm

Shell materialdie-cast aluminum

Weight1Kg

Advantagesمقاومة للغبار, explosion-proof, corrosion-proof

  • تفاصيل المنتج

وصف

S600-ExIR2-UV point type infrared / UV flame detector contains two infrared wavelength sensors and a highly sensitive imported UV/ultraviolet sensor and optical filter. The ultraviolet sensor can respond to ultraviolet radiation at the moment of fire and explosive ignition. The other two infrared sensors, one has the highest sensitivity to the CO2 emission spectrum (4.4μm), and the other interferes with ambient light and heat radiation For detection, the detector makes a composite judgment on the ultraviolet and infrared signals generated in the event of a fire, and performs multi-signal processing in conjunction with the logical comprehensive judgment of the flame flicker frequency to minimize false alarms and the best fire detection performance required. The flame detector has an early warning function for the fire of organic materials such as hydrocarbons and the fire of inorganic materials.

ميزات وظائف

المعلمات الفنية

Response spectral range 4.4μm, 3.8μm, 185-260nm
Response time 6s
Viewing angle range ≤110 °
Detection distance Class I
Ambient temperature -10 ~ 55
Environmental humidity ≤95% RH
Pressure range 86 ~ 106Kpa
جهد العمل DC24V
Working current current≤25mA, alarm current≤35mA
Executive standard GB15631-2008, GB12791-2006
Explosion-proof grade EX d ⅡC T6 Gb
Protection grade IP66
Signal output Switching relay contact output, RS-485 (built-in DIP switch, can set the address of the detector)
Installation method wall or ceiling
Cable outlet thread 20mmX1.5mm free conversion G1 / 2 خياري
Dimensions (190X160X110) mm
Shell material die-cast aluminum
Weight 1Kg
Advantages مقاومة للغبار, explosion-proof, corrosion-proof

Prev: